Project Home

Trackers

Source Code

File Releases

Documents

Wiki

Discussions

Reports

Project Info
Artifact artf4010 : Analog Triggers will not work on AI 2-7 Print Preview
Tracker:Bugs
Title:Analog Triggers will not work on AI 2-7
Description:
The code in the HAL that sets the module for a digital source checks the index against the number of digital headers 
(and remaps the pin by subtracting 10 if it thinks it's on the MXP) regardless of the setting of the AnalogTrigger bit. 
This will result in any AnalogTrigger output index over 10 (any output mode on AI 2-7) to map incorrectly.

This is the cause of the issues documented in these posts:
http://www.chiefdelphi.com/forums/showthread.php?threadid=134316
http://www.chiefdelphi.com/forums/showthread.php?threadid=134340
Submitted By:Kevin O'Connor (FIRST)
Submitted On:02/11/2015 4:13 PM GMT
Last Modified:06/02/2015 3:09 PM GMT
Closed:06/02/2015 3:09 PM GMT

Active Tab Status / Comments Inactive Tab - left sideChange Log Inactive Tab - left sideAssociations Inactive Tab - left sideDependencies Inactive Tab - left sideAttachmentsInactive Tab - right side  
C++ and Java
Status
Planning Folder:*None
3
Closed
Kevin O'Connor (FIRST)
Comments
#3Kevin O'Connor (FIRST): 06/02/2015 3:09 PM GMT
 Action:Update
Closed set to 06/02/2015
Status changed from Fix Commited to Closed
#2Joe Ross (330): 02/15/2015 6:27 AM GMT
 Comment:
Fix in development branch.
 Action:Update
Status changed from Open to Fix Commited
#1Kevin O'Connor (FIRST): 02/11/2015 4:13 PM GMT
 Action:Create